Hummingbird-550

Hummingbird-550Suction tape removal machine

Hummingbird-550

Specialized head removes suction tape quickly and reliably!

  • New concept: removing suction tape with removal tape
  • Peeling from the edge enables removal with minimal force
  • Use resin rollers that do not damage parts
Head Section

Three-step tape removal / 1. Roller moves to the suction tape to be removed. / 2. Roller presses down removal tape, bonding it to the suction tape. / 3. Removal tape is wound up, peeling off and removing the suction tape.

High speed removal of suction tape!

  • High-speed removal of 1 to 1.5 seconds/board!
  • The removed tape adheres to the removal tape and is collected automatically.
  • Enabling labor optimization and automation within the production process

Built-in camera inspection for removal residue

  • A built-in camera compares images before and after tape removal to detect any residual tape.
  • Supports retry operation on areas where residual tape is detected.

Easy teaching

  • Minimizes data creation time through intuitive teaching, requiring only the selection of tape removal locations and patterns from the PCB image.

Easy teaching

Specifications

*Please see the table by scrolling horizontally.

PCBA to be inspected M size
L size ×
Target PCBA Dimensions 50mm (W) x 50mm (D) to 330mm (W) x 250mm (D)
Thickness of PCBA 0.5 to 2.0mm
Maximum weight of PCBA 3kg
Height limit of PCBA (Clearance) Top side 80mm
Bottom side 80mm
Suction tape removal range 330mm (W) to 250mm (D)
(Not possible within 4mm of the PCB edge.)
Removal rate 1.5 sec./piece (our standard conditions)
Usable tape size(Cellophane tape) 12mm×50m, 12mm×70m
Repeatability of positioning ±50μm
Camera Yes
Light source Warm white LED
Flow direction of PCBA Right-to-Left / Left-to-Right
(selectable at the time of order)
Conveyor width adjustment Automatic
Monitor 21.5" wide monitor
PC OS Windows 11 Professional 64bit
Japanese/English(Language is selectable at the time of order.)
Memory 8GB
Machine-to-machine interface SMEMA standard compliant
Environment conditions for operation 10 to 35℃/30 to 80%RH (no condensation)
Environment conditions for storage -10 to 60℃/30 to 80%RH (no condensation)
Power supply AC100 to 240V (single phase) 50/60Hz
Power consumption 350VA(including PC and monitoring)
Air supply Air supply:0.5MPa
Air consumption :5Nℓ/min
Dimensions of main unit
(excluding protrusions)
W1,410×D960×H1,490mm
※At a pass line height of 900mm
Weight (excluding PC and monitor) 245kg

*Please see the table by scrolling horizontally.

Page top